GST Fire Alarm System

Offering you a complete choice of products which include gst di-9201e addressable smoke detector, dc-9103e gst conventional heat detector, di-9301e gst control module, gst-200-2/1 one loop fire alarm system, addressable zone monitor module and gst conventional beam detector.

GST DI-9201E Addressable Smoke Detector

Request Callback

₹ 1200 / Piece Get Latest Price

Product Brochure
Alarm Sensor TypeOptical
Purity98%
Body MaterialABS Plastic
Startup Time (sec)10 sec
BrandGST
Usage/ApplicationIndustrial
Operating VoltageLoop 24V (16V ~ 28V)
Relative Humidity<95%, non condensing
Warranty1 Year
WeightAbout 110 gm
Packaging TypeBox
ModelDI-9201E
Environment Temperature-10 to 50 Deg C
Material of EnclosureABS
We are engaged in offering GST DI-9201E Addressable Smoke Detector to our clients. Our range of all products is widely appreciated by our clients.

DC-9103E GST Conventional Heat Detector

Request Callback

₹ 550 / Piece Get Latest Price

Product Brochure
MaterialABS
Startup Time (sec)10 sec
Operating Temperature-10 DegreeC to 50 DegreeC
Relay OutputsSupervisory Relay
Max Wire Gauge for Terminals1.5 mm
Usage/ApplicationIndustrial
Control KeysSystem Reset
Model Name/NumberDC-9103E
TypeConventional
System ComponentsFire Alarm Control Panel
Operating Voltage24VDC(16VDC~28VDC)
Ingress Protection RatingP2X
Relative Humidity< 95%, non-condensing
WeightAbout 110 gm (with base)
DC-9103E Conventional Rate of Rise and Fixed Temperature Heat Detector is a new generation product of GST. With built-in microprocessor, it works stably by being fixed with highly reliable fire judging program. On detecting a fire signal, it can change its own current to transmit the signal to fire alarm control panel (FACP) or addressable zone monitor unit. The detector keeps illuminating fire LED until it is reset by power-down.

DI-9301E GST Control Module

Request Callback

₹ 2500 / Piece Get Latest Price

Product Brochure
System TypeAddressable
Panel SeriesGST200/1
Panel CapacityLOOP DEVICES
Automation GradeAutomatic
Model Name/NumberDI-9301E
Usage/ApplicationIndustrial
System ComponentsFire Alarm Control Panel
Country of OriginMade in India
BrandGST
Operating VoltageLoop 24VDC (16VDC - 28VDC)
Ingress Protection RatingIP30
Operating Temperature-10 to 55 Deg C
Relative Humidity< 95%, non-condensing
Materials of the EnclosureABS, White (RAL9016)
Dimension85.3 x 78 x 33 mm
WeightAbout 66.5 gm
Features:
  • The dry contact input port can be programmed to NC or NO and monitored. 
  • The input can also be programmed as “self-answering”, which means that the Input port monitoring is disabled, and the module will directly send a “status” signal to FACP when the dry-contact output changes state. 
  • Addressable unit. Address can be programmed in field.  Input port utilizes AD sampling technology for precise testing. 
  • DIN-Rail mounted or Wall mounted. 
  • Standard: EN 54-18:2005 Description With a microprocessor, the DI-9301E Digital Single Input and Output Module (the module) can communicate with fire alarm control panel (FACP), check loop power-cut, control output, circuit faults, logic state of input signals, and state LEDs. On receiving start command from the FACP, it will close the output relay and illuminate the active indicator.

GST-200-2/1 One Loop Fire Alarm System

Request Callback

₹ 41000 / Piece Get Latest Price

Product Brochure
TypeAddressable
Relay OutputsSupervisory Relay
Control KeysSystem Reset
Frequency50Hz/60Hz
Automation GradeAutomatic
Model Name/NumberGST-200-1
Usage/ApplicationIndustrial
System ComponentsFire Alarm Control Panel
Country of OriginMade in India
Input Voltage220V/230VAC
Input Current0.5 A
Fuse2A delay
Dimensions420 x 580 x 202 mm
Description: 
  • 20P data cable connecting with main board. 
  • Red LED, which lights on receiving signals. 
  • Green LED, which lights on sending signals. 
  • RS485 network communication cable (A and B). 
  • 20P data cable connecting with main board. 
  • Standard RS232 interface connecting with GMC. 


Note: You need to include an RS232 card in your first order of GST200-2/1 FACP. Only with this card, device definition and C&E equations can be downloaded from PC. 3.3 Peripheral Devices 3.3.1 A Series of Intelligent Fire Detectors GST200-2/1 can connect with a series of fire detectors, such as I-9102, I-9103, and I-9105R. The detectors mounted in the protected area transmit monitoring message to the FACP through Class A loop. Every detector has its own address with which the FACP can supervise the information of alarm, fault, and normal status of the detectors. 3.3.2 Modules GST200-2/1 can connect with I-9300 Addressable Input Module and I-9301 Addressable Single I/O Module. I-9300 module is used for receiving normally open digital signal from fire protection devices and transmitting the signal back to the fire alarm control panel. I-9301 module is for connecting fire protection devices that need to be controlled by the FACP, such as smoke valve, fresh air valve, and damper valve. It can also receive answer signal from these devices. 3.3.3 Loop Isolator Loop Isolator can remove the shorted part of loop from the whole system to ensure normal operation of other devices and to ascertain the location of the part in fault. After the fault is repaired, the loop isolator can automatically reset the removed part into the system. 3.3.4 Manual Call Points A series of manual call points (such as I-9202) can be connected to the loop of GST200-2/1. When fire is confirmed manually, pressing the glass on the MCP, alarmsignal can be sent to the FACP. After receiving the alarm signal, the FACP will show the number and location of the MCP, and sound alarm.

Addressable Zone Monitor Module

Request Callback

₹ 2700 / Unit Get Latest Price

Product Brochure
Power Supply24 VDC
Monitoring ParametersSmoke
BrandGST
Display TypeAnalog
Model Name/NumberDI-9319E
Input Voltage24VDC
Operating Current1 Amp
Operating Voltage24v
Weight100
DI-9319E Digital Zone Monitor Unit is designed to connect conventional detectors into addressable system. When any device reports fire signal, the module will transmit the signal to the fire alarm control panel which generates fire alarm and displays the address of the module. It is also suitable to connect dry contacts input, collect action or fault signals. The installation points of the module are shown below, Wall-mount and Rail-mount. DIN-35mm rail is applicable. (Z1, Z2) IN & OUT: Loop connection, In & Out, non-polarized (V, G) IN & OUT: 24VDC power supply, V is positive, G is negative I, G: Conventional detectors, polarized Installation Features and Benefits

Gst Conventional Beam Detector

Request Callback

₹ 16500 / Unit Get Latest Price

Range (meter)100m
Usage/ApplicationIndustrial
ColorBlack
MaterialABS
Voltage24 V
Operating Temperature-10 to 50 Deg C
BrandGST
Weight1.3 kg
Country of OriginMade in India
Details:
  • Wide operating voltage range
  • Large protection areas
  • Combination of transmitter & receiver in one housing allows easy optical alignment
  • Intelligent microprocessor based decision making on fire and fault statuses
  • Easy one person installation & operation due to simple calibration and setup processes                

Gst Network Card

Request Callback

₹ 8790 / Unit Get Latest Price

Product Brochure
MaterialPlatic
ColorGreen
Weight100 Gram
Voltage24
Country of OriginMade in India
P-9940A is an optional card for GST200 series control panels, providing two photoelectric isolation RS485 interfaces.  This card shouldn’t be inserted and removed when it is energized.  When entering calibration mode, pressing SK1 key (reset main board), it will display Color CRT OK if registration is successful.  LEDs: 1)Main board communication HL1 LED: Red. It flashes when communicates with main board normally.  2)Master Interface(A1B1)communication HL2 LED: Green. It illuminates steadily when RS485 master interface is in normal communication and there is no message transmitting on the loop. 3)Slave Interface 2(A2B2) communication HL3 LED: Green. It illuminates steadily when RS485 master interface is in normal communication and there is no message transmitting on the loop.  In the network made of those cards, A1B1 connects with the A2B2 of the neighbor control panel. Each of RS485 loop shouldn’t exceed 1200m in all, supporting the network of maximum 32 GST series control panels. 

GST I 9105R Intelligent Beam Detector

Request Callback

₹ 16500 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
MaterialABS
Automation GradeAutomatic
Operating Voltage15 to 28 V (24 VDC Nominal)
Operating Temperature-10 to +50 DegreeC
Relative Humidity<95%, non condensing
BrandGST
Mounting TypeWall Mount
ModelI 9105R
Physical Dimensions95 x 206 x 95 mm (W x H x D)
We are engaged in offering GST I 9105R Intelligent Beam Detector  to our clients. Our range of all products is widely appreciated by our clients.

GST DI-9103E Heat Detector

Request Callback

₹ 1200 / Piece Get Latest Price

Product Brochure
Startup Time (sec)10 sec
Relay OutputsSupervisory Relay
Control KeysSystem Reset
Automation GradeAutomatic
Model Name/NumberDI-9103E
Operating VoltageLoop 24V (16V ~ 28V)
Ambient Temperature-10 ~+ 65 DegreeC
Relative Humidity<95%, non condensing
Material of EnclosureABS
WeightAbout 110 gm
Details:
  • Electrically addressed, can be modified by programmer 
  • Self-diagnostic 
  • Reed switch test 
  • Fire LED allows 360° viewing 
  • Possible to switch off pulling LED 
  • Remote indicator output 
  • 3 classes programmable 
  • LPCB approved at EN54-5 There are four terminals with marks on the base.
  • Loop connection (non-polarized) 
  • Positive terminal of remote indicator 
  • Negative terminal of remote indicator The base is suitable to be installed onto standard European embedded back box, with hole-distance 45mm to 75mm

DI-9103E Intelligent Rate of Rise and Fixed Temperature Heat Detector

Request Callback

₹ 1200 / Piece Get Latest Price

Product Brochure
Startup Time (sec)10 sec
Operating Temperature-10 DegreeC to 50 DegreeC
Relay OutputsSupervisory Relay
Max Wire Gauge for Terminals1.5 mm
Control KeysSystem Reset
Standby Current<0.6mA
Model Name/NumberDI-9103E
TypeAddressable
System ComponentsFire Alarm Control Panel
Operating VoltageLoop 24V (16V ~ 28V)
Ambient Temperature-10 ~ +65 DegreeC
Relative Humidity<95%, non condensing
Material of EnclosureABS
WeightAbout 110 gm
DI-9103E Intelligent Rate of Rise and Fixed Temperature Heat Detector is a new addressable fire alarm device cooperating with GST intelligent fire alarm control panels to build a fire detection system. The detector shows fire alarm by the LED indicator and transmits the signal to the FACP.

DI-9204E GST Manual Call Point

Request Callback

₹ 1900 / Unit Get Latest Price

Product Brochure
Relay OutputsAlarm Relay
Usage/ApplicationIndustrial
Model Name/NumberDI-9204E
ColorRed
Control KeysSystem Reset
Ingress Protection RatingIP43
Operating VoltageLoop 24 V (16V - 28V)
Environmental Temperature-10 to +55 Deg C
Material of EnclosureABS
Relative Humidity< 95%, non condensing
Mounting Hole Distance60 mm
Connecting to the loop of GST fire alarm system, DI-9204E Digital Manual Call Point (MCP) is suitable for public places. When there is a fire, pressing the frangible element on this MCP can send fire signal to fire alarm control panel. After receiving the signal, the control panel will show address information of the MCP and generate alarm sound.

DI-9101E GST Smoke Detector

Request Callback

₹ 1250 / Unit Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
BrandGST
Automation GradeAutomatic
Model Name/NumberDI-9101E
Voltage24 VDC
WeightAbout 110 gm
Operating Voltage24V (16V ~ 28V)
Standby Current<0.8mA
Action Temperature62 Deg C
Environment Temperature-10 to 50 Deg C
Relative Humidity< 95%, non condensing
Material of EnclosureABS

Minimum order quantity: 1 Unit

DI-9101E Intelligent Combined Heat Photoelectric Smoke Detector integrates photoelectric detection, fixed temperature and rate of rise detection technology. The smoke sensor and heat sensor are integrated in mechanism and circuitry structure, provide wide range of application, to detect more types of fire conditions like black smoke with small particles and alcohol flame.

DI-9300E Monitor Module

Request Callback

₹ 1800 / Piece Get Latest Price

Product Brochure
BrandGST
Display TypeAnalog
Model Name/NumberDI-9300E
Operating Temperature-10 to 55 Deg C
Operating VoltageLoop 24VDC (16V - 28V)
WeightAbout 36.8 gm
Ingress Protection RatingIP30
Relative Humidity<95%, non-condensing
Materials of the EnclosureABS, white (RAL9016)
Dimension78 x 45.3 x 28.5 mm
DI-9300E Digital Single Input Module (the module) is used for receiving normally open or normally closed switch signal from fire suppression devices, and transmits these messages to fire alarm control panel (FACP). When a device of this kind is activated, the module can send the output signal through signal loop to FACP to alarm or activate relative devices.

Features:
  • Normally closed input, normally open input can be set through a hand held programmer.
  • Electronically addressing. Addresses can be modified in field.
  • Built-in microprocessor processes messages intelligently.
  • Input terminals apply AD sampling with precise testing.
  • DIN-Rail mounted or Wall mounted.
  • Standard: EN 54-18:2005

GST-NRP00 Fire Alarm Repeater Panel

Request Callback

₹ 17000 / Piece Get Latest Price

Product Brochure
Model Name/NumberGST-NRP00
Operating Temperature0 to 40 Deg C
BrandGST
Dimensions390 x 270 x 100 mm (D x W x H)
Packaging TypeBox
Supply Voltage20VDC~27VDC
System CurrentMax. 0.5A
Display8(Line) x 18 (characters)
Operating Humidity>95%,non condensing

Minimum order quantity: 1 Piece

GST-NRP00 Network Repeater Panel is based on GST network technology, providing remote control and indication of the fire alarm system. A certain network card is required for sitting to the network. GST-NRP00 is flush-mount or surface-mount. Its appearance and the mounting hole are shown here. 1.0mm2 or above fire cable is recommended for communication cable, and 1.5mm2 or above fire cable is recommended for power supply. All cables should be subject to local codes. Installation Data Features and Benefits Recommended Cabling Certificates and Compliance  Gulf Security Technology Co., Ltd. This publication is a generic version in which product information is shown for informational purposes only and does not constitute a specific commitment or guarantee. We are constantly pursuing the improvement of product technology to improve product performance, for which we reserve the right to adjust the configuration and technical information of the related products without notice. In addition, the description of system performance in this publication applies only to the usual situation. As a result, there may be a variety of unpredictable special circumstances in the real world, so the realization of the relevant product performance will depend on the professional investigation and analysis and the design plan. Please contact us and we will be happy to provide you with professional advice.
  • Provide remote display and control of system 
  • Password protected access level 
  • 8X18 characters LCD screen 
  • 15 LEDs to display important information 
  • Functional control of network panels 
  • Network-wide operation: Acknowledge, Silence, Reset. 
  • Flush-mount or surface-mount structure 
  • Meet network protocol by selecting suitable network

GST-IFP4M Single Loop Addressable Fire Alarm Panel

Request Callback

₹ 45000 / Unit Get Latest Price

Usage/ApplicationIndustrial
BrandGST
Model Name/NumberGST-IFP4M
Operating Temperature32-120 Degree F (0-49 DegreeC)
Operating Humidity<93% RH, non-condensing
ColorBlack & White
Country of OriginMade in India
Power Supply120VAC / 60Hz, 220VAC / 50Hz
Max. Current3.0A (120VAC) or 1.5A (220VAC)
LCD Display7" TFT touch screen, 800x480
Dimensions516 x 840 x 180 mm(W x H x D)
Features and Benefits:
  • 242 addressable devices per loop mixing various types of devices,
  • Max. 1452 addresses
  • Support up to 32 ZCP panel with individual programmable buttons
  • & LED indicators. Max 8 ZCP panels for wall mount cabinet
  • 7-inch Touch Screen 800 x 480
  • Support 1-6 loops in Class A style (additional battery box is
  • required for 5/6 loops)
  • Wide range power supply
  • Wall mount with glass door
  • Built-in multiple languages, currently supports English, Spanish,
  • Portuguese and Russian
  • Programing via PC or panel keypad and touch screen
  • USB port for system configuration and firmware update
  • Password and key-protected nonvolatile memory
  • Support USB dongle for securing project database
  • History records of 100,000 events
  • “Walk test”, silent or audible
  • PAS (Positive Alarm Sequence) per point
  • Report device type mismatch and duplicated loop address
  • Optional Redundancy CPU
  • Bulit-in BACnet (Authorization code needs to be ordered
  • separately)
  • Optional Modbus Card
  • Capability of remote downloading site specific data
  • Compatibility with System Sensor’s Bell (SSM24-6)
  • Three colors for cabinet: Gray(default), White, Red.
  • CAN/Fiber Networking, Panel grouping
  • 2 Power Limited Class B Notification Appliance Circuits (NAC),
  • total load Max.2.5A/24VDC. The 2 nd NAC can be set as AUX.
  • 1 Limit to non-monitored input interface

I 9403 Gst Addressable Sounder Cum Strobe

Request Callback

₹ 2300 / Piece Get Latest Price

Product Brochure
BrandGST
Operating VoltageLoop : 24V (20V~28V), Power: 24V (20V~28V)
ColorRed
Model Name/NumberI-9403
Operating Temperature- 10 ~ +50 Deg C
Country of OriginMade in India
Relative Humanity< 95%, non condensing
Enclosure MaterialABS
Dimension110 x 110.4 mm (deep base), 110 x 95.9 mm (shallow base)
Ingress Protection RatingIP33
We are engaged in offering I 9403 Gst Addressable Sounder Cum Strobe to our clients. Our range of all products is widely appreciated by our clients.

C-9403/04 GST Sounder Cum Strobe

Request Callback

₹ 2300 / Unit Get Latest Price

Body MaterialPlastic
Usage/ApplicationIndustrial
Operating Voltage24 V
ColorRed
Model Name/NumberC-9403/04
Country of OriginMade in India
Packaging TypeBox
BrandGST
We are engaged in offering C-9403/04 GST Sounder Cum Strobe to our clients. Our range of all products is widely appreciated by our clients.

C-9104 Conventional Ultraviolet Flame Detector

Request Callback

₹ 7000 / Piece Get Latest Price

Product Brochure
Model Name/Numberc-9104
BrandGST
MaterialPlastic
DimensionRound
Power Source24
Voltage24 Volt
Country of OriginMade in India
C-9104 Conventional Ultraviolet Flame Detectordetects fire by analyzing ultraviolet radiation ofmaterial flaming. It's applicable to places where openfire, fire with intense flame radiation and fire withoutsmoldering stage take place easily, as well as placeswhere quick response to a fire is required. Usedtogether with other detectors, it can sense fire in timeto minimize losses as much as possible.The detector is DC powered, which powers signalprocessing circuit after voltage stabilization, the UVsensor needs 300V voltage or so, which is providedafter boosted by transformer. When there is ultravioletlight on the sensor, it discharges due to photoelectriceffect, and the strength of discharge is in proportionwith the intensity of UV light. Signal processing circuitanalyzes and processes its output signal, thencompares with alarm threshold and outputs alarmsignals. The alarming mode of the detector is currentoutput; it's shorted by internal 680 after alarming
X

Contact Us

Aakash Vashishtha (Proprietor)
J P Fire Safety
Geetanjali Vihar, F 69, Gali No. 04, Khora Colony, Ghaziabad
Noida - 201309, Gautam Buddha Nagar, Uttar Pradesh, India

Get Directions
Send Email
Share: