Prominent & Leading Wholesale Distributor from Noida, we offer zxra morley ias active repeater panel, mi-dczrm addressable zone monitor module, mi-dcmo addressable control output module, dxc4 morley loop panel, morley dxc1 single loop panel and morley honeywell zxra active repeater.

Get Best Quote

Approx. 55,000 / Piece Get Latest Price

Product Brochure
Product Details:
Max Wire Gauge For Terminals2.5 mm
Operating Voltage18 to 32 VDC
Operating Current90 mA (Quiescent) 120 mA (Alarm)
Operating Temperature5 to 45 Deg C
BrandMorley
Weight1.7 kg
System ComponentsFire Alarm Control Panel
Maximum Humidity10% to 93% non-condensing

The Morley-IAS repeaters are compact remote control units for Morley-IAS intelligent multi protocol fire alarm control panels. These units, along with other I/O peripheral devices and theexternal printer further enhance the flexibility and functionality of our fire alarm control panel range.

The repeaters provide an extension to the operation of the fire alarm control panel. There are two types available - passive with indications only and no controls, or active with both controls and indicators. Both display the operational state of the control panel using the 80 character LCD display and the 7 LED status indicators.

In addition to the general status indicators the Active repeater is fitted with key operated "Access Enable" switch for the control functions. Individual buttons are provided for System Reset, Mute, Accept, Sound Alarms, Silence/Re-sound Alarms and Self test. Thus enabling control functions to be duplicated in strategic locations around the installation.

Yes! I am Interested


Get Best Quote

Approx. 5,500 / Piece Get Latest Price

Product Brochure
Product Details:
BrandMorley Honeywell
Usage/ApplicationIndustrial
Model Name/NumberMI-DCZRM
Humidity5% to 95% relative humidity (non-condensing)
Display TypeAnalog
Operating Voltage18 to 28.5 VDC
Weight110 gm
Temperature Range-20 to 60 Deg C

The MI-DCZRM addressable zone monitor module allows a zone of non-addressable devices to communicate with a Morley-IAS protocol analogue addressable system. As a result existing non-addressable zones can be integrated into a Morley-IAS protocol system.

The module monitors a zone of two-wire non-addressable devices. Each MI-DCZRM uses one of 99 available module addresses on a loop. A fault signal will be transmitted to the panel in case of an open circuit or short circuit on the non-addressable zone wiring or when the external fault input is pulled low (can beused for power supply monitoring). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations).

The non-addressable zone can be powered from the analogue communication loop or from an external power supply. Where the non-addressable zone is powered from an external power supply, the communication loop is fully isolated from the non-addressable zone and from the power supply.

The zone monitor module replaces the MI-CZME but can be mounted onto a DIN rail. It can also be powered from the addressable loop and allows integration of non-addressable zones into an addressble system. This module enables non-addressable devices to be monitored by Morley-IAS protocol analogue addressable fire alarm control panels.

Yes! I am Interested


  • +2
Get Best Quote

Approx. 2,900 / Unit Get Latest Price

Product Brochure
Product Details:
Relay OutputsAlarm Relay
Automation GradeAutomatic
Model Name/NumberMI-DCMO
Usage/ApplicationIndustrial
BrandHoneywell
Relative Humidity0 to 95% maximum non-condensing
Operating Voltage15 to 30 VDC
Operating Temperature-20 to 60 Deg C
Weight110 gm
Dimensions93 x 94 x 23 mm
Country of OriginMade in India

The Morley-IAS MI-DCMO control output module is used with the ZX series of intelligent conrol panels to provide either a single alarm circuit or Form C relay.

The MI-DCMO can be used to operte dry contacts for door holders, air handling unit shut down or other similar functions. Optionally the module can be used to supervise wiring to the ouput load providing monitoring of the external load voltage or power supply. If the monitored voltage falls below threshold then a fault condition will be indicated.

Each MI-DCMO uses one of the ninety-nine possible module addresses available on a loop. It responds to regular polling from the conrtol panel indicated by a pulsing LED every successful communication. On command from the control panel the MI-DCMO will disconnect the supervision and connnect the external power supply across the load. The disconnection of the supervision provides a positive indication to the control panel that the relay is activated. The MI-DCMO has a built-in isolator which may be switched out if required.

The MI-DCMO uses a unique mechanical design allowing each module to be mounted either in a wall box (M200-SMB) or on a DIN rail (using M200-DIN). Irrespective of the mounting method chosen, the address switch is both visible and accessible for selection. To help engineers in the maintenance and fault finding process, both the LEDs and the address switches can be viewed without having to remove the cover of the mounting box. The LEDs, being multi colour, provide diagnostic information regarding the status of the output. For ease of installation, testing and maintenance, the field wiring terminals are of a plug in design.

Yes! I am Interested


REQUEST CALLBACK
  • +1
Get Best Quote

Approx. 1.39 Lakh / Piece Get Latest Price

Product Brochure
Product Details:
Relay OutputsAlarm Relay
Model Name/NumberDXC-4
TypeConventional
System ComponentsFire Alarm Control Panel
BrandHoneywell
Dimension391.5 x 390 x 147 mm
Weight (Excluding Batteries)4.5 kg
Mounting Holes3
Relative Humidity5% - 95% non-condensing
Operating Temperature0 to 40 Deg C

The Morley-IAS DX Connexion panel is ideally suited for use in the protection of small to medium sized buildings. All in all, a compact, high performance, feature rich, economical fire alarm control panel designed to help both the installer and the end user.

 

 

The DX Connexion is an enhancement of the Morley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality.

 

 

The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. Simply fix the control panel to the wall, connect the field wiring, power up and in as few as five button presses you can have a compliant, working fire alarm system. The panel’s large graphical display provides a clear menu structure making the whole initial set-up process quick, clear and intuitive.

 

 

Additionally, programming the control panel couldn’t be easier. Complex configuration can be achieved by using either the panel’s mobile phone style key pad or by using the Windows PC programming tool supplied with the panel.


Yes! I am Interested


Get Best Quote

Approx. 65,000 / Piece Get Latest Price

Product Brochure
Product Details:
Control KeysEvacuate
Model Name/NumberDXC-1
TypeConventional
BrandHoneywell
Weight (Excluding Batteries)4 kg
Operating Temperature0 to 40 Deg C
Relative Humidity5% - 95% non-condensing
Dimension260 x 390 x 147 mm

The Morley-IAS DX Connexion panel is ideally suited for use in the protection of small to medium sized buildings. All in all, a compact, high performance, feature rich, economical fire alarm control panel designed to help both the installer and the end user.

The DX Connexion is an enhancement of the Morley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality.

The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. Simply fix the control panel to the wall, connect the field wiring, power up and in as few as five button presses you can have a compliant, working fire alarm system. The panel’s large graphical display provides a clear menu structure making the whole initial set-up process quick, clear and intuitive.

Additionally, programming the control panel couldn’t be easier. Complex configuration can be achieved by using either the panel’s mobile phone style key pad or by using the Windows PC programming tool supplied with the panel.

Yes! I am Interested


Get Best Quote

Approx. 49,000 / Piece Get Latest Price

Product Brochure
Product Details:
Model Name/NumberZxr-A
TypeAddressable
System ComponentsFire Alarm Control Panel
BrandHoneywell
Maximum Humidity10% to 93% non-condensing
Weight1.7 kg (approx)
Operating Voltage18 to 32 VDC
Operating Current90 mA (Quiescent) 120mA (Alarm)
Operating Temperature+5 to 45 Deg C

The Morley-IAS repeaters are compact remote control units for Morley-IAS intelligent multi protocol fire alarm control panels. These units, along with other I/O peripheral devices and theexternal printer further enhance the flexibility and functionality of our fire alarm control panel range.

The repeaters provide an extension to the operation of the fire alarm control panel. There are two types available - passive with indications only and no controls, or active with both controls and indicators. Both display the operational state of the control panel using the 80 character LCD display and the 7 LED status indicators.

In addition to the general status indicators the Active repeater is fitted with key operated "Access Enable" switch for the control functions. Individual buttons are provided for System Reset, Mute, Accept, Sound Alarms, Silence/Re-sound Alarms and Self test. Thus enabling control functions to be duplicated in strategic locations around the installation.

Yes! I am Interested


Get Best Quote

Approx. 2,380 / Piece Get Latest Price

Product Brochure
Product Details:
Model Name/NumberMI-DISO
TypeConventional
System ComponentsFire Alarm Control Panel
BrandHoneywell
Weight62 gm
Operating Voltage15 to 30 Vdc
Operating Temperature-20 to 60 Deg C
Humidity0 to 95% maximum non-condensing
Dimensions93 x 94 x 23 mm (H x W x D)

The Morley-IAS loop isolator module is used on the Morley-IAS intelligent fire alarm control panels to protect the system against wire-to-wire short circuits on the analogue addressable loop wiring.

The fault isolator modules should be placed between groups of sensors on the loop wiring to protect the loop if a short circuit fault occurs. If a short circuit fault occurs, the two isolators located either side of the short circuit fault will automatically sense the voltage drop, open their switches and remove the devices from the rest of the loop. If the line voltage then rises above a fixed threshold, indicating that the short circuit fault is removed, then the isolator module will automatically restore the power to the isolated group of devices.

The MI-DISO isolator uses a unique mechanical design allowing each module to be mounted either in a wall box or on a DIN rail. Irrespective of the mounting method chosen, the address switch is both visible and accessible for selection. To help engineers in the maintenance and fault finding process, both the LEDs and the address switches can be viewed without having to remove the cover of the mounting box. The LEDs, being multi colour, provide diagnostic information regarding the status of the isolator.

Yes! I am Interested


  • +2
Get Best Quote

Approx. 2,500 / Piece Get Latest Price

Product Brochure
Product Details:
Usage/ApplicationIndustrial
BrandHoneywell
Display TypeAnalog
Model Name/NumberMI-DMMI
Operating Temperature5 to 45 Deg C
Operating Voltage230 Vac 50/60 Hz (+-15%)
Weight2 Kg (approx, no batteries fitted)
Dimension318 x 356 x 96 mm
Relative Humidity5% to 95% non condensing

We are engaged in offering Morley Mi-Dmmi Addressable Monitor Module to our clients. Our range of all products is widely appreciated by our clients.

Yes! I am Interested


Get Best Quote

Approx. 1,500 / Piece Get Latest Price

Product Brochure
Product Details:
Alarm Sensor TypeOptical
BrandMorley Honeywell
Humidity10 to 93% relative humidity (non-condensing)
ModelHM/PSE/S2
Operating Voltage Range15 to 28 VDC
Temperature Range-30 to 70 Deg C

S200A incorporates major hardware and software technology driven developments. An advanced optical chamber design is proven in extensive testing to be more efficient, less liable to false alarm due to dust and insects and less susceptible to fault in high air velocities or back pressure. Extensive hydrodynamic modelling has confirmed the greater efficiency of the new chamber and housing shape combination. Large-scale integration of the all-new electronics, through the fully automated surface mount PCB assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers improved quality and reliability. All S200EA detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs, and are mechanically and electrically backwards compatible with existing devices.

Yes! I am Interested


Get Best Quote

Approx. 26,900 / Piece Get Latest Price

Product Brochure
Product Details:
Usage/ApplicationIndustrial
Warranty1 Year
BrandHoneywell
Model Name/Number795-099
Dimensions318 x 356 x 96 mm
Relative Humidity5% to 95% non condensing
Operating Temperature5 to 45 Deg C
Weight2 Kg (approx, no batteries fitted)
Operating Voltage230 Vac 50/60 Hz (+/-15%)
Country of OriginMade in India

Features:
  • Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line
  • Fire and fault outputs - volt-free relay or monitored (optional)
  • Auxiliary power output for ancillary equipment
  • 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.)
  • Space for two option modules
  • Optional 8-way relay module, common or zonal switching
  • Optional 1.5A 4-way sounder module, common or zonal switching
  • Simple to install
  • Robust fire resistant ABS moulded enclosure
  • Battery space for up to 72 hours stand-by
  • 2, 4 or 8 zone versions available

Yes! I am Interested


Get Best Quote

Approx. 82,000 / Unit Get Latest Price

Product Brochure
Product Details:
BrandHoneywell
Dimension391.5 x 390 x 147 mm
Mounting Holes3
Operating Temperature0 to 40 Deg C
Weight (Excluding Batteries)4.5 kg
Relative Humidity5% - 95% non-condensing
ModelMorley-Ias (Dxc2): 2
Country of OriginMade in India

The Morley-IAS DX Connexion panel is ideally suited for use in the protection of small to medium sized buildings. All in all, a compact, high performance, feature rich, economical fire alarm control panel designed to help both the installer and the end user.

The DX Connexion is an enhancement of the Morley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality.

The DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. Simply fix the control panel to the wall, connect the field wiring, power up and in as few as five button presses you can have a compliant, working fire alarm system. The panel’s large graphical display provides a clear menu structure making the whole initial set-up process quick, clear and intuitive.

Additionally, programming the control panel couldn’t be easier. Complex configuration can be achieved by using either the panel’s mobile phone style key pad or by using the Windows PC programming tool supplied with the panel. 

Additional Information:
  • Item Code: 9954661
  • Delivery Time: 2 Days

Yes! I am Interested


Get Best Quote

Approx. 2,500 / Piece Get Latest Price

Product Brochure
Product Details:
BrandHoneywell
Usage/ApplicationIndustrial
Model Name/NumberMI-DMMIE
Humidity0 to 95% maximum non-condensing
Display TypeAnalog
Warranty1 Year
Operating Temperature-20 to 60 Deg C
Operating Voltage15 to 30 VDC
Weight110 gm
Dimensions93 x 94 x 23 mm

We are engaged in offering MI-DMMIE Addressable Monitor Module  to our clients. Our range of all products is widely appreciated by our clients.

Yes! I am Interested


  • +5
Get Best Quote

Approx. 2 Lakh / Piece Get Latest Price

Product Brochure
Product Details:
Max Wire Gauge For Terminals2.5 mm
Relay OutputsSupervisory Relay
Control KeysSystem Reset
Automation GradeAutomatic
Model Name/NumberMA-8000-2
Usage/ApplicationIndustrial
TypeAddressable
System ComponentsFire Alarm Control Panel
Storage Temperature-10 to 50 Deg C
Humidity5% - 95% non-condensing
Operating Temperature-5 to 40 Deg C
Dimension398 x 483 x 217.5 mm
Country of OriginMade in India

The system offers fire detection solutions integrated for many applications, like hotels, offices, hospitals, industrial environments and production facilities. MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CanBus technology. This standard, originally designed for operation in industrial environments, makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms. The system is certified in compliance with the standards EN 54-2, EN 54-4. 

Yes! I am Interested


  • +3
Get Best Quote

Approx. 47,600 / Piece Get Latest Price

Product Brochure
Product Details:
Relay OutputsSupervisory Relay
Max Wire Gauge For Terminals2.5 mm
Control KeysSystem Reset
Automation GradeAutomatic
Model Name/NumberMA-LIB2-02
Usage/ApplicationIndustrial
TypeAddressable
System ComponentsFire Alarm Control Panel
Operating Temperature-5 to 40 Deg C
Humidity5% - 95% non-condensing
Storage Temperature-10 to 50 Deg C
Main Display7" touch screen
Country of OriginMade in India

We are engaged in offering MA-LIB2-02 Morley Max Loop Card  to our clients. Our range of all products is widely appreciated by our clients.

Yes! I am Interested


  • +3
Get Best Quote

Approx. 49,800 / Piece Get Latest Price

Product Brochure
Product Details:
TypeAddressable
Max Wire Gauge For Terminals2.5 mm
Relay OutputsSupervisory Relay
Operating Temperature-5 to 40 Deg C
ModelMA-LCD 7
Humidity5% - 95% non-condensing
Storage Temperature-10 to 50 Deg C
BrandHeneywell
Country of OriginMade in India

MAx panels are Multi-processor Fire Detection System suitable for system configurations of a wide range of installations. The system offers fire detection solutions integrated for many applications, like hotels, offices, hospitals, industrial environments and production facilities. MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CanBus technology. This standard, originally designed for operation in industrial environments, makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms. The system is certified in compliance with the standards EN 54-2, EN 54-4. 

Yes! I am Interested


REQUEST CALLBACK
  • +4
Get Best Quote

Approx. 1,800 / Piece Get Latest Price

Product Brochure
Product Details:
Alarm Sensor TypePhotoelectric
Automation GradeAutomatic
Body MaterialABS Plastic
Product TypeDetector
ColorBrown
Brand/CompanyHoneywell
Voltage24 Volt
SensorSmoke & Heat
I Deal InNew Only
Country of OriginMade in India

The S200A photoelectric smoke detector has a completely new detection chamber design, the result of many years of research and development. This delivers improved responsiveness, reduced sensitivity changes caused by settling dust and reduced false alarms resulting from ingress of insect and other debris. The plug-in unit uses sophisticated processing circuitry that incorporates smoothing filters to help eliminate transient environmental noise conditions that can be the cause of unwanted alarms. The devices are managed by embedded software running complex algorithms that further improve resilience to false alarms and improve detection speed.

Yes! I am Interested


  • +1
Get Best Quote

Approx. 6,000 / Piece Get Latest Price

Product Brochure
Product Details:
BrandMorley
Operating Voltage24
Body MaterialPlastic
ColorRed & White
Model Name/NumberMI-WSS-PR-N
Weight200 GRAM
Country of OriginMade in India

Morley-IAS’s new modular range of Intelligent AV warning devices provides easier system
confi guration and flexibility. A common base across AV and detectors is available, allowing for easier installation and ordering.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. 2,540 / Unit Get Latest Price

Product Details:
Relay OutputsTrouble Relay, Alarm Relay
Normal Loop Voltage24 VDC
Automation GradeAutomatic
Model Name/NumberMI-DMMI
Usage/ApplicationIndustrial
System ComponentsFire Alarm Control Panel
Warranty1 Year
BrandMorley Honeywell
Country of OriginMade in India

We are engaged in offering Morley Monitor Module to our clients. Our range of all products is widely appreciated by our clients.

Yes! I am Interested


Get Best Quote

Approx. 3,200 / Piece Get Latest Price

Product Brochure
Product Details:
Usage/ApplicationFire Alarm System
Model Name/NumberHM-MCP-GLASS
Surface Mounting Dimensions89 x 93 x 59.5 mm (WxHxD)
Semi-flush Mounting Dimensions89 x 93 x 27.5 mm (W x H x D)
Operating Temperature0 to 49 Deg C
Operating Voltage15 to 32 VDC max
Weight110 gm
Relative Humidity10% - 93% non-condensing
BrandHoneywell

The call point is an addressable break glass manual call point which has a simple rotary decade switch at the rear of the unit for addressing. A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved. The HM-MCP-GLASS Call Point is designed to provide a manual alarm interface to Morley IAS’s fire alarm control panel. Installation efficiency, compliance with the latest standards are at the heart of the call point range.

Yes! I am Interested


Get Best Quote

Approx. 3,200 / Unit Get Latest Price

Product Brochure
Product Details:
Minimum Order Quantity10 Unit
Usage/ApplicationFire Alarm System
ColorRed
Weight110 gm
Surface Mounting Dimensions89 x 93 x 59.5 mm (WxHxD)
ModelHM/MCP/GLASS
Operating Voltage15V to 32Vdc max
Semi-flush Mounting Dimensions89 x 93 x 27.5 mm (WxHxD)
Operating Temperature0 to 49 Deg C
Relative Humidity10% - 93% non-condensing

The call point is an addressable break glass manual call point which has a simple rotary decade switch at the rear of the unit for addressing. A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved. The HM-MCP-GLASS Call Point is designed to provide a manual alarm interface to Morley IAS’s fire alarm control panel. Installation efficiency, compliance with the latest standards are at the heart of the call point range.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. 3,200 / Unit Get Latest Price

Product Brochure
Product Details:
BrandMorley Honeywell
Usage/ApplicationFire Alarm System
Model Name/NumberHM/MCP/GLASS
ColorRed
Weight110 gm
Operating Temperature0 to 49 Deg C
Semi-flush Mounting Dimensions89 x 93 x 27.5 mm (WxHxD
Relative Humidity10% - 93% non-condensing
Operating Voltage15V to 32 VDC max
Packaging TypeBox
Surface Mounting Dimensions89 x 93 x 59.5 mm (WxHxD)
Country of OriginMade in India

We are engaged in offering Morley Manual Call Point to our clients. Our range of all products is widely appreciated by our clients.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. 30,000 / Piece Get Latest Price

Product Brochure
Product Details:
TypeAddressable
Usage/ApplicationIndustrial
Warranty1 Year
Model Name/Number795-099
BrandMorley
Packaging TypeBox
Dimension391.5 x 390 x 147mm (H x W x D)
Country of OriginMade in India

We are engaged in offering 795-099 Morley Network Card to our clients. Our range of all products is widely appreciated by our clients.

Yes! I am Interested


 






Corporate Brochure




 

 

Send SMS
Aakash Vasishta  (Proprietor)
J P Fire Safety
D-180 Sec-63 A Mob-9911678151
Sector 63 A, Noida - 201309 , Uttar Pradesh , India
Send E-mail
Share Us:
X