Call 0804861857186% Response Rate

Morley LIte Fire Alarm System


Our product range includes a wide range of hml/pse honeywell smoke detectors, dxc2 morley 2 loop panel, hml/ptse morley lite honeywell multi detector, hml/rhse heat detector, hml/ptse multi detector and hml/100/2a fire alarm panel.

Get Best Quote

Approx. 900 / Piece Get Latest Price

Product Brochure
Product Details:
BrandHoneywell
Usage/ApplicationIndustrial Premises
Weight105 gm (plus 60g for B401 base)
Humidity5 to 95% Relative Humidity (non condensing
Diameter102 mm
ModelHML/PSE
Operating Voltage Range8 to 30VDC (Nominal 12/24VDC)
Application Temperature Range-30 to 70 Deg C
Height38 mm (plus 9mm for B401 base)
Country of OriginMade in India

The HML/PSE photoelectric smoke detector forms part of the Honeywell Morley Lite range of addressable detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing detector technology.

The HML/PSE photoelectric detector incorporates an Application Specific Integrated Circuit (ASIC). Combined with the latest state of the art optical chamber the detector provides efficient and accurate detection of fires with a high level of resilience to non-fire environmental influences. 

The HML/PSE detector is backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations.

The HML/PSE detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status - Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. The Green LED can be programmed for blink/no blink operation.

Drift compensation’ algorithms are one of the key features of the HML/PSE detector. These algorithms ensure a consistent alarm sensitivity threshold for periods between service intervals. This provides the user with both a reduction in the frequency of nuisance alarms and maintenance savings by extending the period before cleaning of the detector chamber is required.

The sensitivity of a smoke detector is critical to its overall performance, this is reflected in both its ability to detect real fire conditions and its resilience to non-fire stimuli. The HML/PSE’s performance can be optimised for it’s application by selecting from one of three preset alarm thresholds - Low, Medium and High, offering greater stability and optimum performance within the environment in which it has been installed. The selection is easily achieved through the use of a remote hand-held tool.

The remote hand-held programming unit can also be used to gain access to other advanced features. The features available include: read/write last maintenance date, read chamber contamination level, read value of thermal element and perform an alarm test.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. 82,000 / Piece Get Latest Price

Product Brochure
Product Details:
Relay OutputsSupervisory Relay
Model Name/NumberDXC2
Usage/ApplicationIndustrial
System ComponentsFire Alarm Control Panel
Weight (Excluding Batteries)4.5 kg
ColorRAL 9002 - Grey white
Mounting Holes3
Operating Temperature0 to 40 Deg C
BrandHoneywell
Relative Humidity5% - 95% non-condensing
Dimensions391.5 x 390 x 147 mm
Country of OriginMade in India

The Morley-IAS DX Connexion panel is ideally suited for use in the protection of small to medium sized buildings. All in all, a compact, high performance, feature rich, economical fire alarm control panel designed to help both the installer and the end user.

The DX Connexion is an enhancement of the Morley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality.

The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. Simply fix the control panel to the wall, connect the field wiring, power up and in as few as five button presses you can have a compliant, working fire alarm system. The panel’s large graphical display provides a clear menu structure making the whole initial set-up process quick, clear and intuitive.

Additionally, programming the control panel couldn’t be easier. Complex configuration can be achieved by using either the panel’s mobile phone style key pad or by using the Windows PC programming tool supplied with the panel.

Yes! I am Interested


Get Best Quote

Approx. 990 / Piece Get Latest Price

Product Brochure
Product Details:
Startup Time (sec)10 sec
BrandHoneywell
Usage/ApplicationIndustrial Premises
Weight105 gm (plus 60g for B401 base)
Humidity5 to 95% Relative Humidity (non condensing)
Diameter102 mm
ModelHML/PTSE
Operating Voltage Range8 to 30VDC (Nominal 12/24VDC)
Height38mm (plus 9mm for B401 base)
Application Temperature Range-30 to 70 Deg C

The HML/PTSE photoelectric smoke/thermal detector forms part of  the HML Series of Addressable detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing detector technology.

The HML/PTSE photoelectric smoke/thermal detector incorpor ates an optical chamber and a thermal element, which in turn are continually monitored by an on board processor by using algorithms developed specifically for the unit. An alarm signal is only enabled iin the detector once the processor is satisfied that an incipient fire has been detected. By using a combination of inputs, the incidence of nuisance alarms is reduced while at the same time, the response time to an actual fire is also improved.

The HML/PTSE and other detectors in the HML Series range are backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations. The HML/PTSE detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status - Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. The Green LED can be programmed for blink/no blink operation.

Drift compensation’ algorithms are one of the key features of the HML/PTSE detector. These algorithms ensure a consistent alarm sensitivity threshold for periods between service intervals. This provides the user with both a reduction in the frequency of nuisance alarms and maintenance savings by extending the period before cleaning of the detector chamber is required.

The sensitivity of a smoke detector is critical to its overall performance, this is reflected in both its ability to detect real fire conditions and its resilience to non-fire stimuli. The HML/PTSE’s performance can be optimised for it’s application by selecting from one of three preset alarm thresholds - Low, Medium and High, offering greater stability and optimum performance within the environment in which it has been installed. The selection is easily achieved through the use of a remote hand-held tool.

The remote hand-held programming unit can also be used in conjunction with the HML Series range of detectors to gain access to other advanced features. The features available include: read/write last maintenance date, read chamber contamination level, read value of thermal element and perform an alarm test.

Yes! I am Interested


REQUEST CALLBACK
  • +1
Get Best Quote

Approx. 950 / Piece Get Latest Price

Product Brochure
Product Details:
Minimum Order Quantity10 Piece
Startup Time (sec)10 sec
Operating Temperature-20 DegreeC to 60 DegreeC
Automation GradeSemi-Automatic
ModelHML/RHSE
Humidity5 to 95% Relative Humidity (non condensing)
Operating Voltage Range8 to 30VDC (Nominal 12/24VDC)
Application Temperature Range-30 to 70 Deg C

The HML/RHSE thermal detector forms part of the HML Series range of addressable detectors. This range of detectors has been produced using the latest in manufacturing and design t echniques, pushing out the boundaries of existing detector technology.The HML/RHSE thermal detector incorporates an Application Specific Integrated Circuit (ASIC). Combined with the latest in thermal element technology the detector provides efficient and accurate detection of fires, especially in environments   such as bars or kitchens where smoke detectors are inappropriate due to the high level of airborne contamination.The HML/RHSE and other detectors in the HML Series range are backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations. The HML/RHSE detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status - Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. The Green LED can be programmed for blink/no blink operation.The remote hand-held programming unit can also be used in conjunction with the HML Series range of detectors to g  ain access to other advanced features. The features available include: read/write last maintenance date, read value of thermal element and perform an alarm test.Each unit can be given a unique address that will be displayed on the Honeywell Morley Lite Panel LCD whenever the detector is in alarm.All the features via the hand-held programming unit are achieved effectively and effortlessly without the need to remove the detector or having to gain direct physical access (other than by the use of ‘No Climb Products’ or similar servicing tool), saving valuable commissioning/maintenance time.They provide the end user with the confidence to know that his system is being regularly serviced and that it is operating at its optimum level, with minimum disruption to his own business activities.

Yes! I am Interested


REQUEST CALLBACK
  • +1
Get Best Quote

Approx. 1,100 / Piece Get Latest Price

Product Brochure
Product Details:
Alarm Sensor TypePhotoelectric
BrandHoneywell
Usage/ApplicationIndustrial Premises
MaterialBayblend FR11
Weight105g (plus 60g for B401 base)
Humidity5 to 95% Relative Humidity (non condensing)
Diameter102 mm
Operating Voltage Range8 to 30VDC (Nominal 12/24VDC)
Height38mm (plus 9mm for B401 base)
Application Temperature Range-30 to 70 Deg C

The HML/PTSE photoelectric smoke/thermal detector forms part of  the HML Series of Addressable detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing detector technology.The HML/PTSE photoelectric smoke/thermal detector incorporates an optical chamber and a thermal element, which in turn are continually monitored by an on board processor by using algorithms developed specifically for the unit. An alarm signal is only enabled iin the detector once the processor is satisfied that an incipient fire has been detected. By using a combination of inputs, the incidence of nuisance alarms is reduced while at the same time, the response time to an actual fire is also improved.The HML/PTSE and other detectors in the HML Series range are backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations. The HML/PTSE detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status - Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. The Green LED can be programmed for blink/no blink operation.Drift compensation’ algorithms are one of the key features of the HML/PTSE detector. These algorithms ensure a consistent alarm sensitivity threshold for periods between service intervals. This provides the user with both a reduction in the frequency of nuisance alarms and maintenance savings by extending the period before cleaning of the detector chamber is required.The sensitivity of a smoke detector is critical to its overall performance, this is reflected in both its ability to detect real fire conditions and its resilience to non-fire stimuli. The HML/PTSE’s performance can be optimised for it’s application by selecting from one of three preset alarm thresholds - Low, Medium and High, offering greater stability and optimum performance within the environment in which it has been installed. The selection is easily achieved through the use of a remote hand-held tool.The remote hand-held programming unit can also be used in conjunction with the HML Series range of detectors to gain access to other advanced features. The features available include: read/write last maintenance date, read chamber contamination level, read value of thermal element and perform an alarm test.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. 16,500 / Piece Get Latest Price

Product Brochure
Product Details:
Usage/ApplicationIndustrial
Model Name/NumberHML/100/2A
Operating Voltage230V-AC +/- 20% Output current 2A maximum, Alarm Load 1A Maximum
Operating Temperature0 to 49 Deg C
Relative Humidity5% to 95% Non-Condensing
Weight5.8 Kg Approx. (No Battery Fitted)
Dimensions (H x W x D)360 x 422 x 122.8 mm (Front Facia), 360 x 380 x 92.3 mm (Back Box)
ConstructionPowder coated Cold Rolled STEEL 1.2mm thick

Honeywell Morley Lite is a Compact, High Performance, Feature enriched Fire Alarm Control Panel designed to meet the Fire Detection Addressability.

Honeywell Morley-Lite Fire Detection Control Panel series is ideally suited for Small to Medium Sized Buildings, Residential Complexes, Banks, Healthcare, Restaurants, Retail Stores etc. Morley Lite panels communicates via LiteSpeedTM protocol with Morley Lite detectors and devices.

Morley Lite Panel is built with Combination of quick installation, enhanced feature set and advanced programming which allows installer to meet demands of the end user with flexibility in configuration. Equipped with configurable remote monitoring inputs, programmable relays, delay setting for alarm verification, software isolation of class B circuit and NAC outputs, mapping of NAC to specific class B circuits, password protections etc.

End users get clear visible indications, easy to operate functions to activate the control buttons, customizable class B circuit text via text inserts to meet building naming conventions. Reliable and trouble free system built as per latest safety standards of industry which ensures system is safe and protected. Internal memory lock feature to restrict changes to fire panel configuration by any intruder without key lock.

Yes! I am Interested


REQUEST CALLBACK
Get Best Quote

Approx. 860 / Piece Get Latest Price

Product Brochure
Product Details:
Startup Time (sec)5 sec
Operating Temperature-20 DegreeC to 60 DegreeC
Max Wire Gauge for Terminals2.5 mm
Operating Voltage (VDC)24 VDC
ShapeRound
Control KeysSystem Reset
Diameter102 mm
Automation GradeAutomatic
Model Name/NumberHML/RHSE
ColorWhite
BrandHoneywell
Body MaterialPlastic
Humidity5 to 95% Relative Humidity (non condensing)
Operating Voltage Range8 to 30VDC (Nominal 12/24VDC)
Application Temperature Range-30 to 70 Deg C
Height48 mm (plus 9mm for B401 base

The HML/RHSE thermal detector forms part of the HML Series range of addressable detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing detector technology.

The HML/RHSE thermal detector incorporates an Application Specific Integrated Circuit (ASIC). Combined with the latest in thermal element technology the detector provides efficient and accurate detection of fires, especially in environments such as bars or kitchens where smoke detectors are inappropriate due to the high level of airborne contamination.

The HML/RHSE and other detectors in the HML Series range are backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations. The HML/RHSE detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status - Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. The Green LED can be programmed for blink/no blink operation.

The remote hand-held programming unit can also be used in conjunction with the HML Series range of detectors to g  ain access to other advanced features. The features available include: read/write last maintenance date, read value of thermal element and perform an alarm test.

Each unit can be given a unique address that will be displayed on the Honeywell Morley Lite Panel LCD whenever the detector is in alarm.

All the features via the hand-held programming unit are achieved effectively and effortlessly without the need to remove the detector or having to gain direct physical access (other than by the use of ‘No Climb Products’ or similar servicing tool), saving valuable commissioning/maintenance time.